 | Our catalogues |  |  | |
|
|  |
|
|
|
 |
 |
Ali Elite |
|
 |
|
|
Line Interactive UPS Tower/19” Rack Mount Versions
|
|
|
The ALI Elite Series is a fully microprocessor controlled, line interactive AVR technology UPS with pure sine wave output providing safe, clean and reliable power to your sensitive electronic equipment. Available in both tower and rackmounted versions with features including fast battery recharge capability, input frequency auto sense and optional external SNMP interface. Typical applications include small servers, work stations, CAD/CAM stations, telephone systems and general office or industrial equipment.
Advanced RS-232 interface combined with AlphaMon complementary software features local utility power and UPS graphical display status, controlled system shut-down, remote administrator alert, utility power quality log and scheduled system shut down/reboot. The ALI Elite Series is fully compliant to international safety and EMC standards and offers a quality cost effective solution to your power needs.
- Advanced Buck and Boost Function for Automatic Voltage Regulation
- Surge protected Port for FAX, Modem and Network Equipment
- Hot-Swap battery capability
- Advanced Battery Management (ABM)
- RS-232 Interface to enable monitoring and controlled shut down
|
|
 |
|
|
|
| Modell Tower: |
ALI Elite
600 |
ALI Elite
800 |
ALI Elite
1000 |
- |
ALI Elite
1500 |
ALI Elite
2000 |
ALI Elite
2500 |
ALI Elite
3000 |
| 19” Rack Mount: |
- |
ALI Elite
800 RM |
- |
ALI Elite
1250 RM |
ALI Elite
1500 RM |
ALI Elite
2000 RM |
- |
- |
Input |
|
|
|
|
|
|
|
|
| Capacity: |
600VA/
360W |
800VA/
480W |
1000VA/
600W |
1250VA/
750W
|
1500VA/
900W |
2000VA/
1200W
|
2500VA/
1500W |
3000VA/
1800W |
Batterie |
|
|
|
|
|
|
|
|
| DC Voltage: |
24V |
24V |
24V |
24V |
36V |
48V |
48V |
48V |
Backup Time |
|
|
|
|
|
|
|
|
| 80% Load: |
11 |
7 |
5 |
10 |
4 |
5 |
6 |
8 |
| 50% Load |
20 |
14 |
10 |
21 |
9 |
10 |
12 |
15 |
Dimensions/Weight |
|
|
|
|
|
|
|
|
| Dimensions: |
|
|
|
|
|
|
|
|
| Tower (mm) |
|
|
|
|
|
|
|
|
| W (mm): |
140 |
140 |
140 |
- |
170 |
170 |
170 |
(2x) 170 |
| D (mm): |
436 |
436 |
436 |
- |
450 |
450 |
450 |
(2x) 450 |
| H (mm): |
210 |
210 |
210 |
- |
226 |
226 |
226 |
(2x) 226 |
| 19“ Rackmount |
|
|
|
|
|
|
|
|
| W (mm): |
- |
483 |
- |
483 |
483 |
483 |
- |
- |
| D (mm): |
- |
381 |
- |
381 |
381 |
381 |
- |
- |
| H (mm): |
- |
130 |
- |
130 |
130 |
130 |
- |
- |
| Weight: |
|
|
|
|
|
|
|
|
| Tower (kg): |
13,8 |
14,5 |
15,0 |
- |
25,0 |
30,0 |
30,0 |
20,2+25,4 |
| 19“ Rackmount |
- |
18 |
- |
23,5 |
26,1 |
28,4 |
- |
- |
Environment |
|
|
|
|
|
|
|
|
| Audible Noise: |
<40dB(A)
(at 1m) |
<40dB(A)
(at 1m) |
<40dB(A)
(at 1m) |
<40dB(A)
(at 1m) |
<40dB(A)
(at 1m) |
<40dB(A)
(at 1m) |
<40dB(A)
(at 1m) |
<40dB(A)
(at 1m) |
| Technische Spezifikationen |
| Input |
|
| Voltage: |
220V/230V/240V nominal selectable |
| Voltage Range: |
±25% at nominal line input, single phase |
| Frequency: |
50Hz or 60Hz, ±5Hz (auto sensing) |
| Unit Input Protection: |
Fuse or breaker |
Output |
|
| Frequency (on battery):: |
50Hz or 60Hz, ±0.5% |
| Voltage (on battery): |
Pure sine wave at ±5% of nominal, -10% of nominal after low battery warning |
| Voltage Regulation (AVR): |
AVR automatically increase output voltage 15% above input voltage if line voltage is –9 to –25% of nominal
AVR decrease output voltage 15% below input voltage if line voltage is 9 to 25% of nominal |
Filtering & Protection |
|
| Spike Protection: |
320Joules, 2ms |
| Overload Protection: |
Automatic shutdown if overload exceeds 110% of nominal at 20sec and 125% at 2sec |
| Transfer Time: |
2 to 4ms (typical) including detection time |
| Short Circuit: |
UPS output cut off immediately or input fuse (or breaker) protection |
Battery |
|
| Type: |
Hot swappable, sealed, maintenance free lead acid, with 3 to 5 years lifetime |
| Protection: |
Automatic self-test and deep discharge protection, replace battery indicator |
| Typical Recharge Time: |
4hrs (to 90% of full capacity) |
Alarm |
|
| Battery Backup:: |
Slow beeping sound (about 0.25Hz) |
| Battery Low: |
Rapid beeping sound (about 1.00Hz) |
| Overload: |
Continuous beeping sound |
Interface |
|
| RS-232: |
Bi-directional communication port (optional SNMP network adaptor) |
| LED Indicators: |
Overload, Backup, Replace Battery, Buck AVR, Line Normal, Boost AVR, Load Bar Graph, Power Bar Graph |
Environment |
|
| Operation Conditions: |
3,500m max. altitude, 0 to 95% humidity non-condensing, 0 to 40°C ambient temperature |
| Storage Condition: |
15,000m max. altitude, 0 to 95 % humidity non-condensing, -15 to 48°C ambient temperature |
| Certification: |
Safety (EN 50091-1, EN 60950), EMC (EN 50091-2, EN50022/B, CISPR 22) |
Warranty |
|
| 24 Months |
|
|
|
|
|
|